When
you put the MASTER SW pushbutton switch in the ON position:
-
The
ECB starts the power-up test.
-
The
APU fuel pump system is energized
-
The
APU air inlet door opens approximately 25s.
When
you put the START pushbutton switch in the ON position:
-
The
ECB energizes the back-up start contactor and the start contactor.
-
The
contactors energize the starter motor and the APU starter motor starts to turn.
-
The
de-oil valve opens (if oil temp is below 6.6 deg C or fuel temp below -12.2 deg C or altitude above 20,000 ft ).
At
7% speed, the ECB:
-
The
ECB energizes the ignition system
-
Opens
the fuel shutoff solenoid valve.
-
Controls
the fuel flow to the APU with the start acceleration control logic.
At
50% speed, the ECB:
-
De-energizes
the start contactor (above 20,000 ft at 58%) which switches off the starter
motor and the ECB accelerates the APU automatically.
-
De-energizes
the back-up start contactor 10KA, after 5 seconds.
At
60% speed, the ECB:
-
De-energizes
the ignition unit
-
De-energizes
the de-oil solenoid (if opened).
At
95 % + 2 s of the nominal APU speed:
-
The
ECB controls and monitors the APU automatically.
-
The
green AVAIL legend in the START pushbutton switch comes on.
-
The
blue ON legend in the START pushbutton switch goes off.
-
The
APU bleed valve is ready for operation.
-
The
APU generator is ready for operation.